| Auteur | Rechercher : Djokic, Bran Islav1; Rechercher : Parks, Harold1 |
|---|
| Affiliation | - Conseil national de recherches Canada. Science des mesures et étalons
|
|---|
| Format | Texte, Article |
|---|
| Conférence | Conference on Precision Electromagnetic Measurements, July 8-13, 2018, Paris, France |
|---|
| Sujet | AC shunt; current measurement; measurement standards; calibration; measurement uncertainty; current comparator; calculable resistor |
|---|
| Résumé | This paper describes a calibration system for AC shunts using digital sampling. It provides bot h ratio errors and phase displacements of a shunt under test with respect to a reference shunt. ln its basic configuration, the calibration system operates at currents of up to 10 A and frequencies of up to IO kHz. The expanded uncertainties (k = 2) of the described calibration system arc estimated to be better than 30 µA/A for magnitude and 30 µrad for phrase at 10 kHz, and lower than these at lower frequencies. |
|---|
| Date de publication | 2018-07 |
|---|
| Maison d’édition | The Conference |
|---|
| Dans | |
|---|
| Langue | anglais |
|---|
| Publications évaluées par des pairs | Oui |
|---|
| Numéro NPARC | 23004093 |
|---|
| Exporter la notice | Exporter en format RIS |
|---|
| Signaler une correction | Signaler une correction (s'ouvre dans un nouvel onglet) |
|---|
| Identificateur de l’enregistrement | b470b4c1-35b4-4a41-80af-17d3ba384957 |
|---|
| Enregistrement créé | 2018-09-27 |
|---|
| Enregistrement modifié | 2020-03-16 |
|---|