DOI | Trouver le DOI : https://doi.org/10.1117/12.2562773 |
---|
Auteur | Rechercher : Rundquist, Nils-Erik; Rechercher : Wright, Shelley A.; Rechercher : Schöck, Matthias; Rechercher : Surya, Arun; Rechercher : Lu, Jessica; Rechercher : Turri, Paolo; Rechercher : Chapin, Edward L.1; Rechercher : Chisholm, Eric M.; Rechercher : Do, Tuan; Rechercher : Dunn, Jennifer S.; Rechercher : Ghez, Andrea; Rechercher : Hayano, Yutaka; Rechercher : Johnson, Chris; Rechercher : Larkin, James E.; Rechercher : Riddle, Reed L.; Rechercher : Sohn, Ji Man; Rechercher : Suzuki, Ryuji; Rechercher : Walth, Gregory; Rechercher : Zonca, Andrea |
---|
Affiliation | - Conseil national de recherches du Canada. Herzberg en astronomie et en astrophysique
|
---|
Format | Texte, Article |
---|
Conférence | Ground-based and Airborne Instrumentation for Astronomy VIII, December 14-18, 2020, Online Only, United States |
---|
Description physique | 15 p. |
---|
Sujet | infrared:imaging; data:simulator; instrumentation: near-infrared; imaging:photometric; giant segmented mirror telescopes: Thirty Meter Telescope; point spread functions; IRIS Consortium; Thirty Meter Telescope; infrared imaging spectrograph; adaptive optics; imaging systems; monte carlo methods; device simulation; infrared telescopes; iterated function systems |
---|
Résumé | The InfraRed Imaging Spectrograph (IRIS) is a first-light instrument for the Thirty Meter Telescope (TMT) that will be used to sample the corrected adaptive optics field by the Narrow-Field Infrared Adaptive Optics System (NFIRAOS) with a near-infrared (0.8 - 2.4 µm) imaging camera and integral field spectrograph. To better understand IRIS science specifications we use the IRIS data simulator to characterize relative photometric precision and accuracy across the IRIS imaging camera 34”x34” field of view. Because the Point Spread Function (PSF) varies due to the effects of anisoplanatism, we use the Anisoplanatic and Instrumental Reconstruction of Off-axis PSFs for AO (AIROPA) software package to conduct photometric measurements on simulated frames using PSF-fitting as the PSF varies in single-source, binary, and crowded field use cases. We report photometric performance of the imaging camera as a function of the instrumental noise properties including dark current and read noise. Using the same methods, we conduct comparisons of photometric performance with reconstructed PSFs, in order to test the veracity of the current PSF-Reconstruction algorithms for IRIS/TMT. |
---|
Date de publication | 2020-12-13 |
---|
Maison d’édition | SPIE |
---|
Dans | |
---|
Série | |
---|
Langue | anglais |
---|
Publications évaluées par des pairs | Oui |
---|
Exporter la notice | Exporter en format RIS |
---|
Signaler une correction | Signaler une correction (s'ouvre dans un nouvel onglet) |
---|
Identificateur de l’enregistrement | ad843644-c4fb-45bb-9ca9-f7545d6149fa |
---|
Enregistrement créé | 2022-07-07 |
---|
Enregistrement modifié | 2022-07-07 |
---|