| DOI | Trouver le DOI : https://doi.org/10.1109/CPEM.1990.110045 |
|---|
| Auteur | Rechercher : Miljanic, P. N.; Rechercher : So, E.1; Rechercher : Moore, W. J. M.1 |
|---|
| Affiliation | - Conseil national de recherches Canada. Institut des étalons nationaux de mesure du CNRC
|
|---|
| Commanditaire | Rechercher : Institute of Electrical and Electronics Engineers; Rechercher : National Research Council Canada |
|---|
| Format | Texte, Résumé |
|---|
| Conférence | CPEM'90, Conference on Precision Electromagnetic Measurements, June 11-14, 1990, Ottawa, Ontario, Canada |
|---|
| Résumé | An electronic technique which greatly increases the apparent permeability of a magnetic core of a current transformer, without a galvanic connection to either of the usual primary or secondary winding circuits, is described. The number of turns and turns ratio can be selected independently as desired. Means are available for examining the waveform of the magnetizing current for the presence of even harmonics, thus indicating possible remanence or direct currents in the windings. Application of the technique to transformer voltage dividers is also discussed. |
|---|
| Date de publication | 1990 |
|---|
| Maison d’édition | IEEE |
|---|
| Dans | |
|---|
| Langue | anglais |
|---|
| Publications évaluées par des pairs | Oui |
|---|
| Numéro du CNRC | NRC-INMS-1544 |
|---|
| Numéro NPARC | 8900276 |
|---|
| Exporter la notice | Exporter en format RIS |
|---|
| Signaler une correction | Signaler une correction (s'ouvre dans un nouvel onglet) |
|---|
| Identificateur de l’enregistrement | 3a02b360-3583-4b39-a3bb-8038a59e9aed |
|---|
| Enregistrement créé | 2009-04-22 |
|---|
| Enregistrement modifié | 2025-12-18 |
|---|