| Download | - View final version: A numerical study on the axial force development at beam-end shear connections during a large compartment fire experiment (PDF, 2.4 MiB)
|
|---|
| DOI | Resolve DOI: https://doi.org/10.4224/40004125 |
|---|
| Author | Search for: Ming, Xiyue M.1ORCID identifier: https://orcid.org/0009-0006-2182-5193; Search for: Nan, Zhuojun2ORCID identifier: https://orcid.org/0000-0001-8189-5448; Search for: Sun, Rui3ORCID identifier: https://orcid.org/0000-0001-9444-0100; Search for: Manes, Martina1ORCID identifier: https://orcid.org/0000-0003-2302-1720; Search for: Dai, Xu1ORCID identifier: https://orcid.org/0000-0002-9617-7681 |
|---|
| Affiliation | - University of Liverpool
- Delft University of Technology
- Artec Fire
|
|---|
| Format | Text, Article |
|---|
| Conference | SiF 2026, 14th International Conference on Structures in Fire, May 18-21, 2026, Kingston, Ontario, Canada |
|---|
| Subject | beam-end shear connections; axial forces; finite element modelling; steel-concrete composite floor structure; large compartment fires |
|---|
| Abstract | Axial force development at beam-end shear connections is critical to the structural fire response of steel-concrete composite floor structures, as sufficient connection ductility is required to maintain the load path and prevent sudden failure. However, this force development remains difficult to quantify at the system level. This study investigates axial forces at the connections via three full-scale composite floor fire tests conducted by the National Institute of Standards and Technology (NIST). The tests had the same structural layouts and loading conditions but differed in slab reinforcement and fire protection schemes. Axial forces at selected beam-end connections were estimated using strain gauges close to the column base via analytical calculations. Moreover, validated finite element (FE) models using VULCAN were utilised to further investigate those axial forces to extend the investigated parameters for more parametric studies at the system level. Our analytical analysis of the three NIST experiments found that solely applying fire protection to individual steel beam members would only delay and prolong the duration of maximum axial forces at beam-end connections. The FE parametric studies revealed that axial forces are more sensitive than global deflections to parameters such as concrete strength and slab reinforcement ratio. Our study highlights that connection force demands cannot be inferred solely from deflections and must be explicitly assessed via robust structural fire analysis. |
|---|
| Date published | 2026 |
|---|
| Publisher | National Research Council Canada |
|---|
| Copyright statement | |
|---|
| In | |
|---|
| Language | English |
|---|
| Peer reviewed | Yes |
|---|
| Export citation | Export as RIS |
|---|
| Report a correction | Report a correction (opens in a new tab) |
|---|
| Record identifier | ddfd40ad-69af-42cd-978a-492f1726bcb2 |
|---|
| Record created | 2026-11-03 |
|---|
| Record modified | 2026-11-13 |
|---|