Download | - View final version: Quality control in preparing masonry mortar (PDF, 1.8 MiB)
|
---|
DOI | Resolve DOI: https://doi.org/10.4224/20378627 |
---|
Author | Search for: Davison, J. I.1 |
---|
Affiliation | - National Research Council of Canada
|
---|
Format | Text, Technical Report |
---|
Physical description | 6 p. |
---|
Subject | Mortar; Masonry; mortar; standards; quality control; safety factors |
---|
Abstract | Quality control during mortar preparation can be improved by adherence to recommendations in Canadian Standards Association Standard A179 concerning on-site storage of materials, batching, and mixing procedures. The Specification contains a test method that will assist the mixer operator in determining sand bulking, and methods that the inspector can use to prepare specimens for compression tests and to determine the ratio between aggregate and cementitious material in fresh mortar. Proper use of these procedures and test methods will ensure more consistent mortar properties, improve the image of masonry in the eyes of the designer, minimize embarrassing colour variations, and could ultimately contribute to the reduction of safety factors in design codes. |
---|
Publication date | 1977-09 |
---|
Publisher | National Research Council of Canada. Division of Building Research |
---|
Series | |
---|
Translation of | |
---|
Language | English |
---|
Peer reviewed | No |
---|
NRC number | NRC-IRC-1311 |
---|
NPARC number | 20378627 |
---|
Export citation | Export as RIS |
---|
Report a correction | Report a correction (opens in a new tab) |
---|
Record identifier | 93ba7acd-4e0b-4308-8b4f-71b61fdc413f |
---|
Record created | 2012-07-24 |
---|
Record modified | 2023-01-19 |
---|