Abstract | Cross Laminated Timber (CLT), which is well suited for construction of tall buildings, is becoming a more popular construction material in North America. However, to ensure comfortable living conditions, sound insulation measures are necessary. The study presented here compares results of direct impact sound insulation of 5- and 7-ply CLT floors covered with different a concrete toppings on various interlayers. Improvements of up to 21dB in Weighted Normalized Impact Sound Pressure Level (Ln,w) were observed using a newly proposed reference floor for CLTs. Furthermore, the improvements of floor coverings on CLT floors are compared to those achieved on other types of construction, such as the reference concrete floor. The improvements of Ln,w tend to be higher on the concrete floors than on the CLT floors tested. These and other findings will be presented. |
---|
Publication date | 2014-11-19 |
---|
In | |
---|
Language | English |
---|
Peer reviewed | Yes |
---|
NPARC number | 21275935 |
---|
Export citation | Export as RIS |
---|
Report a correction | Report a correction (opens in a new tab) |
---|
Record identifier | 90cfede6-5413-4e57-921b-1ae79e6d5a66 |
---|
Record created | 2015-08-11 |
---|
Record modified | 2020-04-22 |
---|