| Download | - View final version: Trial of refrigerated jet engine test bed (PDF, 2.8 MiB)
|
|---|
| DOI | Resolve DOI: https://doi.org/10.4224/40003915 |
|---|
| Author | Search for: Macaulay, G. A.1 |
|---|
| Affiliation | - National Research Council Canada. National Aeronautical Establishment
|
|---|
| Format | Text, Memorandum |
|---|
| Physical description | 8 p. |
|---|
| Abstract | At 0°C O.A.T. and using the full refrigeration plant capacity, an equilibrium temperature depression of 9.4°C was obtained with 124 lb/sec. air mass flow. The overall coefficient of the brine to air heat exchanger U based on air side area was 2.4 Btu. per hr. ft² °F. |
|---|
| Publication date | 1957-05-31 |
|---|
| Publisher | National Research Council Canada |
|---|
| Series | |
|---|
| Language | English |
|---|
| Peer reviewed | No |
|---|
| Export citation | Export as RIS |
|---|
| Report a correction | Report a correction (opens in a new tab) |
|---|
| Record identifier | 8f2d91e1-2422-4af4-b557-17d093dcfdcf |
|---|
| Record created | 2025-12-01 |
|---|
| Record modified | 2025-12-01 |
|---|