Download | - View final version: Measuring corrosion levels of ductile iron pipes using scanned images (PDF, 4.1 MiB)
|
---|
DOI | Resolve DOI: https://doi.org/10.4224/20374408 |
---|
Author | Search for: Mak, H.1; Search for: Wong, B.1; Search for: Kruithof, S.1; Search for: Krys, D.1; Search for: Liu, Z. |
---|
Affiliation | - National Research Council of Canada. NRC Institute for Research in Construction
|
---|
Format | Text, Technical Report |
---|
Physical description | 80 p. |
---|
Subject | Pipes and pipelines; corrosion measurement method; scan image; image processing; point cloud image data |
---|
Abstract | This report documents the findings and the results of an engineering exercise to develop a process to measure the corrosion depth of buried samples from their scanned images before and after burial. The recommended method consists of 5 steps which combine the power of a Konica Minolta scanner, PolyWorks and software developed in Matlab. PolyWorks is mainly used as a human interface for manipulating and aligning point cloud data sets. The use of PolyWorks reduces software development to a minimum. Software developed in Matlab is mainly for image transformation and corrosion depth/volume calculation. |
---|
Publication date | 2008-11-01 |
---|
Publisher | National Research Council of Canada |
---|
Series | |
---|
Language | English |
---|
Peer reviewed | No |
---|
NRC number | NRC-IRC-20000 |
---|
NPARC number | 20374408 |
---|
Export citation | Export as RIS |
---|
Report a correction | Report a correction (opens in a new tab) |
---|
Record identifier | 842b0ab8-bbbb-473c-9890-5a64bfd1045a |
---|
Record created | 2012-07-23 |
---|
Record modified | 2022-09-13 |
---|