Download | - View final version: Fire spread in wall/floor joints of multi-family dwellings (PDF, 1.2 MiB)
|
---|
DOI | Resolve DOI: https://doi.org/10.4224/20331683 |
---|
Author | Search for: Sultan, M. A.1; Search for: Séguin, Y. P.1; Search for: Leroux, P.1 |
---|
Affiliation | - National Research Council of Canada. NRC Institute for Research in Construction
|
---|
Format | Text, Technical Report |
---|
Physical description | 66 p. |
---|
Abstract | This report presents the results of 3 full-scale fire tests conducted at the Institute for Research in Construction, National Research Council of Canada on double stud party wall/floor joints. The assemblies were tested in a floor furnace using the CAN/ULC-S101-M89 temperature-time relationship. This study was part of a joint research project on the fire and sound flanking at the wall/floor joints in double stud wall assemblies. |
---|
Publication date | 1998-06-01 |
---|
Publisher | National Research Council of Canada |
---|
Series | |
---|
Language | English |
---|
Peer reviewed | No |
---|
NRC number | NRC-IRC-8897 |
---|
NPARC number | 20331683 |
---|
Export citation | Export as RIS |
---|
Report a correction | Report a correction (opens in a new tab) |
---|
Record identifier | 3e0f0545-9188-4606-8297-3a796b48c3b3 |
---|
Record created | 2012-07-18 |
---|
Record modified | 2022-11-07 |
---|