| Download | - View final version: Model-based adaptive kinematic transformation for multi-degree-of-freedom hybrid fire simulation with ongoing high temperature test development (PDF, 1.0 MiB)
|
|---|
| DOI | Resolve DOI: https://doi.org/10.4224/40004124 |
|---|
| Author | Search for: Ma, Raymond1ORCID identifier: https://orcid.org/0009-0006-7279-9992; Search for: Park, Jamin2ORCID identifier: https://orcid.org/0000-0002-9332-4930; Search for: Kwon, Oh-Sung1ORCID identifier: https://orcid.org/0000-0002-3292-9194 |
|---|
| Affiliation | - University of Toronto
- Myongji University
|
|---|
| Format | Text, Article |
|---|
| Conference | SiF 2026, 14th International Conference on Structures in Fire, May 18-21, 2026, Kingston, Ontario, Canada |
|---|
| Subject | hybrid simulation; performance-based fire design; multi-DOF control; adaptive error compensation |
|---|
| Abstract | Hybrid fire simulation (HFS) combines physical and numerical substructuring to evaluate global structural behaviour under fire, overcoming the cost of full-scale tests and the limitations of isolated component testing. However, multi-degree-of-freedom (MDOF) interface control remains challenging due to actuator interaction and evolving thermo-mechanical response during heating. This paper presents the model-based adaptive kinematic transformation method developed by Park et al. [1], which continuously identifies the actuator stroke–deformation relationship used to map target interface deformations to actuator commands, and summarizes its implementation in MDOF hybrid fire testing and practical limitations under thermal loading. The methodology was verified in a small-scale hybrid fire test of a steel beam substructure representative of realistic boundary conditions. The results showed improved convergence during ambient loading and stable test progression during heating when a capped-iteration safeguard was introduced. However, the verification also showed that a purely mechanical adaptive mapping becomes less effective when thermally induced deformation dominates the measured interface response. Key implementation considerations, including iteration control and thermal drift, are summarized. Finally, an ongoing high-temperature hybrid fire test series is outlined to investigate the operating limits of the method and support temperature-informed extensions. |
|---|
| Date published | 2026 |
|---|
| Publisher | National Research Council Canada |
|---|
| Copyright statement | |
|---|
| In | |
|---|
| Language | English |
|---|
| Peer reviewed | Yes |
|---|
| Export citation | Export as RIS |
|---|
| Report a correction | Report a correction (opens in a new tab) |
|---|
| Record identifier | 0683a333-0128-45c9-a81d-4cabadca7987 |
|---|
| Record created | 2026-11-03 |
|---|
| Record modified | 2026-11-13 |
|---|